Introduction
The LCD5501Z keypad presents system status
using an LCD-style display along with fixed
words and numbers. The keypad can be used
on security systems with up to 32 zones. The
LCD5501Z is compatible with the following DSC
security systems:
PC580 v2.3 and higher
PC1555 v2.3 and higher
PC5008 v2.3 and higher
PC5010 v2.0 and higher
PC5015 v2.2 and higher
Specifications
Connects to control panel via 4-wire Keybus
One keypad zone input
Current draw: 45mA (standby)
Optional tamper version
Five programmable function keys
Ready (green), Armed (red) and Trouble (yellow)
status lights
Installation
Unpacking
The LCD5501Z package includes the following
parts:
One LCD5501Z keypad
Four mounting screws
One keypad inner door label
One set of Fire, Auxiliary and Panic key labels
Mounting
You should mount the keypad where it is acces-
sible to designated points of entry and exit.
Once you have selected a dry and secure
location, perform the following steps to mount
the keypad:
1. Remove the keypad backplate by loosening the
screw located at the base of the unit.
2. Secure the keypad backplate to the wall in the
desired location. Use the screws provided.
3. Before attaching the keypad to its backplate,
complete the keypad wiring as described in the
next section.
Installation Instructions
WARNING: Please refer to the System Installation Manual for information on limitations regarding product
use and function and information on the limitations as to liability of the manufacturer.
LCD5501Z
Version 1.0
WWW.DIYALARMFORUM.COM
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - WWW.DIYALARMFORUM.COM

IntroductionThe LCD5501Z keypad presents system statususing an LCD-style display along with fixedwords and numbers. The keypad can be usedon security

Pagina 2

2Wiring1. Before beginning to wire the unit, ensure thatall power (AC transformer and battery) isdisconnected from the control panel.2. Connect the fo

Pagina 3

3Programming the KeypadThere are several programming options avail-able for the LCD5501Z keypad. These aredescribed below. Record all your programming

Pagina 4

4Alarms Displayed While Armed OptionYou can disable the display of alarms on thekeypad when the system is armed. The displayof alarms is enabled by de

Pagina 5

5Door Chime SoundsYou can program the LCD5501Z keypad tomake different door chime sounds for individualzones, or groups of zones. Each LCD5501Zkeypad

Pagina 6

6[000] Keypad Programming1. Enter [*][8][Installer’s code]2. Enter [000] to go to keypad programming[0] Keypad EnrollmentValid entries are 01-18; e.g.

Pagina 7

7[*] Door Chime Sound Programming1. Enter [*][8][Installer’s code][*]2. Enter 2-digit zone number [01] - [32], then select door chime sound option [1]

Pagina 8

© 1999 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6416-665-8460 • 1-800-387-3630 • www.dscgrp.comPrinted in C