DSC Power8 PC5OO5 Manuale di Installazione Pagina 12

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 40
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 11
8
Section 4: Advanced System
Programming
Zone Attributes
Zone Attribute Defaults (Y = Option ON; N = Option OFF):
Section Zone # Zone Audible/ Steady/ Chime Bypass Force Swing Tx. Delay Wireless Cross Zn
Type** Silent Pulsed No No No No No No No
12345 6789
[101] 01 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________|
[102] 02 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[103] 03 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[104] 04 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[105] 05 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[106] 06 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[107] 07 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[108] 08 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[109] 09 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[110] 10 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[111] 11 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[112] 12 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[113] 13 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
[114] 14 ( )
I________I I________| I________| I________| I________| I________| I________| I________I I________I
Attribute: 123456 789
ON Audible Steady Chime Bypass Force Swing Tx. Delay Wireless Zn Cross Zn
OFF Silent Pulsed No No No No No No No
Zone Type:
00 Null Zone NNNNNNNNN
01 Delay 1 YYYYNYNNN
02 Delay 2 YYYYNYNNN
03 Instant YYYYNYNNN
04 Interior Y Y N Y N Y N N N
05 Int. Stay/Away Y Y N Y Y Y N N N
06 Dly. Stay/Away Y Y N Y Y Y N N N
07 Dly. 24hr Fire (Hardw.) Y NNNNNNNN
08 Stand. 24hr Fire (Hardw.) Y NNNNNNNN
09 24hr Superv. N Y N N Y N N N N
10 24hr Superv. Buzzer N Y N Y N N N N N
11 24hr Burglary Y Y N Y N N N N N
12 24hr Holdup N Y NNNNNNN
13 24hr Gas Y NNNNNNNN
14 24hr Heating Y NNNNNNNN
15 24hr Medical Y Y NNNNNNN
16 24hr Panic Y Y NNNNNNN
17 24hr Emergency Y Y NNNNNNN
18 24hr Sprinkler Y Y NNNNNNN
19 24hr Water Y Y NNNNNNN
20 24hr Freeze Y Y NNNNNNN
21 24hr Latching Tamper Y Y NNNNNNN
22 Momentary KeyswitchNNNNYNNNN
23 Maintained KeyswitchNNNNYNNNN
24 LINKS Answer NNNNYNNNN
25 Interior Delay YYNYNYNNN
26 24hr Non-alarm NNNNYNNNN
27 Delayed 24hr Waterflow Y NNNNNNNN
28 Instant 24hr Waterflow Y NNNNNNNN
29 Auto Verified Fire YNNNNNNNN
30 Fire Supervisory NNNNNNNNN
31 Day Zone Y Y N Y Y Y N N N
87 Dly. 24hr Fire (Wireless) Y NNNNNNYN
88 Stand. 24hr Fire (Wireless) Y NNNNNNY N