G E T T I N G S T A R T E D6Bell Output Terminals - BELL+ and BELL-These terminals provide up to 3 Amps of current at 12 VDC (rated 11.6-12.6 VDC for
G E T T I N G S T A R T E D72.3 Wire Routing for Power & Non-Power LimitedAll wiring entry points are designated by the arrows. All circuits are
G E T T I N G S T A R T E D8• PC5921 EXT/R Door Box Audio Station: 35 mA • LCD5502Z2 Keypad: 25 mA• PC5108 Zone Module: 35 mA • LCD5501Z32-433: 260m
G E T T I N G S T A R T E D9Step 1 - Enter Installer Programming.Step 2 - Press [000] for Keypad Programming.Step 3 - Enter [1] to [5] to select Func
G E T T I N G S T A R T E D102.10.2 Single End Of Line (EOL) Resistors (5600ΩΩΩΩΩ) NORMALLY CLOSEDCONTACT WITH5600 Ω END OF LINERESISTORANY ZTERMINAL
G E T T I N G S T A R T E D112.10.6 Keyswitch Zone WiringΩΩZones may be programmed to be used as keyswitcharming zones and must be wired according to
Keypad CommandsS E C T I O N 312All keypads provide complete information and control of the alarm panel. The panel can be completely pro-grammed via
K E Y P A D C O M M A N D S133.3 Auto BypassWhen the system is armed and any zone or zone(s) on the system have been programmed as Stay/Away thepanel
K E Y P A D C O M M A N D S14A description of the various troubles are as follows:Trouble [1] - Service Required This light will be on if any of th
K E Y P A D C O M M A N D S15[✱]+[4] Door Chime On/OffIf enabled the keypad will beep 5 times rapidly when a zone is tripped and restored. The panel
LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc
K E Y P A D C O M M A N D S16[✱]+[6] User FunctionsThis keypad command can be used to program several different functions. The following are the item
K E Y P A D C O M M A N D S17Special Note: [✱] [7] [2] – Command Output Option #2:Press [✱] [7] [2] [Access Code, if required] to activate all output
K E Y P A D C O M M A N D S183.5.1 Function Key OptionsThe following is a list of Function Key options available:[00] - Null KeyThe key is not used a
K E Y P A D C O M M A N D S19[18] Identified Voice Prompt HelpThis feature can only be programmed if both the Escort5580 and the PC5928 Audio Matrix
How to ProgramS E C T I O N 420The following section of the manual describes how to enter Installer Programming and how to program the various sectio
H O W T O P R O G R A M21[1] to enter A[✱] to return to decimal mode (Ready light is solid)[3] to enter the digit 3[0] to enter the digit 0 as a fil
Program Descriptions22S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper
P R O G R A M D E S C R I P T I O N S23Do not wire 24-Hour Supervisory zones on keypad zone terminals.[10] 24 Hour Supervisory Buzzer Zone Whether
P R O G R A M D E S C R I P T I O N S24Wireless Zone Determines if the zone is a wireless zone or a hardwired zone. Allows the panel to generate lo
P R O G R A M D E S C R I P T I O N S255.6 Communicator - Reporting FormatsEach central station phone number of the panel can be programmed to report
Table of ContentsiPC5010 Control Panel Hookup Diagram ... iiSection 1 - System Introduction1.1 Specifications ...
P R O G R A M D E S C R I P T I O N S26Communicator Format ... Section [360]SIA Sends Automatic Reporting Cod
P R O G R A M D E S C R I P T I O N S275.7.4 OpeningsThe panel will transmit an Opening Reporting Code to indicate a Partition(s) has been disarmed.
P R O G R A M D E S C R I P T I O N S28A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from theKey
P R O G R A M D E S C R I P T I O N S29The panel will immediately go on line and begin the download process unless the Call Back option is enabled. I
P R O G R A M D E S C R I P T I O N S30• 8 low current outputs available with the PC5208 Output Module• 4 high current outputs available with the PC5
P R O G R A M D E S C R I P T I O N S31[11] System Tamper The PGM Output will activate when any Tamper condition is present and will de
P R O G R A M D E S C R I P T I O N S32Attribute [2], Partition 2 controls event is defaulted OFF for all output options.Attribute [3] must be ON (de
P R O G R A M D E S C R I P T I O N S33Test Transmission Reporting Codes ... Section [352]Test Transmission Time of Day ...
P R O G R A M D E S C R I P T I O N S34The event buffer can be viewed three different ways. It can be viewed through an LCD keypad, printed on-site u
P R O G R A M D E S C R I P T I O N S35If armed, the panel will do nothing until the next day at the Auto-Arm Time, when it will check again.If disar
Hookup DiagramP C 5 0 1 0 C O N T R O L P A N E LLCD5501Z32-433CompatibleSystem KeypadsCompatible System Keypads: PC5508Z/KP5508Z, PC5516Z/KP5516Z,P
P R O G R A M D E S C R I P T I O N S36must be programmed with a hex decimal “F”.5.26.1 Using LINKS1000 as the Sole CommunicatorThe panel can be prog
P R O G R A M D E S C R I P T I O N S37Step 3 - Enter Sections [82], [83], [84] and [85] to enable or disable supervision.The wireless zone attribute
P R O G R A M D E S C R I P T I O N S385.32.1 Factory Default Main Panel (Hardware)Step 1 - Remove AC and battery from the panel.Step 2 - Remove all
39SIA Format (Level 2—Hardcoded)This format will send the Account Code along with itsdata transmission. At the receiver, the transmissionwould look si
40REPORTINGV CODES* A/R = alarms/restorals; T/R = tamper/restorals; O/C = openings/closings; Maint. = maintenance;Misc. = miscellaneous; Test = test t
UL Listed Commercial and Residential InstallationsThe installation requirements listed below must be met for the following grades of service.Grade A L
©2002 Digital Security Controls Ltd.Toronto, Canada • www.dsc.comTechnical Support: 1-800-387-3630Printed in Canada 29002711 R005FCC COMPLIANCE S
1System IntroductionS E C T I O N 11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• 8 Fully Programmable Zones• 38 Access
S Y S T E M I N T R O D U C T I O N2Additional Features• Auto Arm by Partition at Specified Time• Keypad Activated Alarm Output and Communicator Test
S Y S T E M I N T R O D U C T I O N31.2.4 PC5100 Addressable Service Interface ModuleThe PC5100 will allow addressable multiplex loop devicesto be ad
S Y S T E M I N T R O D U C T I O N41.2.10 LINKS1000 Cellular CommunicatorThe LINKS1000 Cellular Communicator provides an efficient, cost-effective m
Getting StartedS E C T I O N 25The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation