PC4010 v3.0 • Installation Manual
DLS-2 v1.3
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual should be carefully read.
Vedere la pagina 0
1 2 3 4 5 6 ... 51 52

Sommario

Pagina 1 - DLS-2 v1.3

PC4010 v3.0 • Installation ManualDLS-2 v1.3WARNING: This manual contains information on limitationsregarding product use and function and information

Pagina 2 - WARNING Please Read Carefully

62.7 Programmable Output WiringThe PGM output is a programmable terminal and willconnect to +12V when activated. The terminal can sink amaximum curren

Pagina 3 - Table of Contents

Section 2: Installation and Wiring7SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 For longer wireruns, you cansplit theaddressabledevi

Pagina 4 - PC4010 Wiring Diagram

8The EGND terminal must be connected to earth groundto enable ground fault detection. A Ground Fault troublewill be indicated if any conductor on the

Pagina 5 - Section 1: Introduction

9Section 3: How to Program 3.1 Introduction to ProgrammingThe PC4010 is programmed via a menu system. Use thearrow keys (<>) to scroll through d

Pagina 6 - 2.2 Terminal Descriptions

103.4 Programming Hexadecimal DataHexadecimal or “Hex” digits are often required for aprogramming item, such as telephone numbers andreporting codes.

Pagina 7

11Section 4: Module Enrollment4.1 Enrolling Keypads and ModulesOnce the wiring of all keypads and modules is complete,they must be enrolled on the sys

Pagina 8 - 2.5 Zone Wiring

124.3 Confirming ModulesRef # [0202] then scroll to desired moduleIn case module numbers were not recorded, you can ver-ify this information through t

Pagina 9 - 2.6 Specialized Zone Wiring

13Section 5: Partitions and Zones5.1 Zone SupervisionRef # [000204] “Zone Supervision”The control panel must be instructed to supervise eitherNo End o

Pagina 10 - 2.8 AML Device Wiring

14Scroll to the partition to be deleted, then press [*]. Whena partition is deleted, the programming assigned to itwill not be erased. If the partitio

Pagina 11 - DC) and can

Section 5: Partitions and Zones15SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 [0] Clear Display will clear the entire label.[1] Clea

Pagina 12 - 2.14 Lithium Batteries

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is you

Pagina 13 - Section 3: How to Program

16NOTE: Waterflow zones always require single EOLresistors regardless of any other programming. Referto the wiring diagram or Section 2.9 “Zone Wiring

Pagina 14

Section 5: Partitions and Zones17SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 • Swgr Shut Down – Swinger shutdown. After the zonehas

Pagina 15 - Section 4: Module Enrollment

18Section 6: Keypad Operation6.1 Partition KeypadsA partition keypad is a keypad that is assigned to a parti-tion. The partition keypad will primarily

Pagina 16 - 4.4 Enrolling AML Devices

Section 6: Keypad Operation19SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 6.4 Keypad BlankingRef #: [000200]When the Keypad Blanking

Pagina 17 - 5.1 Zone Supervision

20When the option is disabled, the alarm memory will onlybe displayed when the system is disarmed.6.9 Zone Bypass DisplayRef #: [000200]Enable the Byp

Pagina 18 - 5.4 Zone Programming

Section 6: Keypad Operation21SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Command Output X (X=1-8) (13-20)This function key provides

Pagina 19

22Section 7: Installer and Access CodesNOTE: Security codes should be changed from their default settings to ensure the security of the system. Do not

Pagina 20

Section 7: Installer and Access Codes23SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ter code can only be changed via installer’s pro

Pagina 21

24Section 8: Arming and Disarming8.1 Arming and Disarming OptionsRef #: [0100XX01] where XX = Partition 01-04The following arming and disarming option

Pagina 22 - Section 6: Keypad Operation

25Section 9: Entry and Exit DelayUpon arming, the panel will begin the Exit Delay. If the “Exit Delay Aud” option is enabled, the keypad will beep eve

Pagina 23 - 6.8 Alarm Memory Display

iTable of ContentsSection 1: Introduction 11.1 Out Of The Box ...11.2 Specification

Pagina 24 - 6.10 Function Key Programming

26Section 10: System Programming10.1AC/DC Power OptionsRef # [000200]The following options are used to determine the powersettings for the system. Pre

Pagina 25

Section 10: System Programming27SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 10.4Event MessagesThe following event messages can be m

Pagina 26 - 7.4 Access Code Options

28Periodic Tx DaysRef #: [0004020400] Enter the number of days between test transmissions.Valid entries are from 001 to 255. The default setting is 00

Pagina 27 - 7.5 Access Levels

29Section 11: Programmable Outputs11.1Main Panel OutputsThe main panel has three programmable outputs: Bell,SAUX+, and PGM1. Adding PC4216/PC4204/PC47

Pagina 28 - 8.2 Automatic Arming

30TLM and Alarm (14)The output will activate when a telephone line trouble ispresent and an alarm occurs on any of the selected parti-tions.Failure To

Pagina 29

Section 11: Programmable Outputs31SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 a) the PGMs are enabled for all the same partitionsOR

Pagina 30 - 10.3 Clock Options

32Section 12: Communications ProgrammingAll options concerning communications can be programmed in the following sections, including telephone numbers

Pagina 31 - 10.8Test Transmissions

Section 12: Communications Programming33SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 reporting code when the zone is restored. (Defa

Pagina 32 - 10.12 Hourly Print

34Tone Delay before attempting to redial. If disabled, thepanel will not search for busy tone when dialing thetelephone number. (Default = No)• 1300 H

Pagina 33 - 11.1Main Panel Outputs

Section 12: Communications Programming35SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 If the SIA format is selected, the panel can be

Pagina 34

iiPC4010 Wiring DiagramNOTE: Do not remove the foam from the back of the circuit board.

Pagina 35 - 11.3Output Pulse Times

36Section 13: DownloadingNOTE: DLS-2 v1.3 is required13.1Downloading OptionsDownloading Telephone Number Ref #: [000302]Enter the telephone number for

Pagina 36 - 12.3Dialing Parameters

37Section 14: Event Scheduling Event scheduling allows for a variety of timed events tooccur on specific dates and at specific times. Openingsand clos

Pagina 37

3814.3Open/Close SuppressionRef #: [001000]Open/Close Suppression will prevent the communica-tion of openings or closings for the partitions following

Pagina 38 - 12.6Communicator Formats

39Section 15: LINKS Communications15.1LINKS1000 (Cellular Communications)When using a LINKS1000 Cellular Communicator as aprimary or backup means of c

Pagina 39 - 12.7Reporting Codes

40Section 16: Diagnostics and Troubleshooting16.1General DiagnosticsRef #: [04]The diagnostics function is designed to help you trackdown any problems

Pagina 40 - Section 13: Downloading

Section 16: Diagnostics and Troubleshooting41SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 battery trouble occurs, the panel will not

Pagina 41 - Section 14: Event Scheduling

42Appendix A: Reporting CodesNotes on Contact IDThe following is a list of Contact ID reporting codes. Thefirst digit (in parentheses) will automatica

Pagina 42 - 14.3Open/Close Suppression

43* A/R = alarms/restorals; O/C = openings/closings; O = other** PPP = partition number; UUU = user number (user 1000=999); ZZZ = zone numberRef. # Re

Pagina 43

44Appendix B: Zone Reporting CodesFor notes on Contact ID and SIA reporting codes, see Appendix A.* If Contact ID is used, the above reporting codes a

Pagina 44 - 16.3Hardware Reset

45Appendix C: ASCII Characters

Pagina 45 - 16.5System Fault Squawk

1Section 1: Introduction1.1 Out Of The BoxPlease verify that the following components are includedin the PC4010 package.❑ 1 PC4050C or PC4001C cabinet

Pagina 46 - Appendix A: Reporting Codes

46IndexAAccess Codegrand master 22guard 22options 22second master 22walk test 22Access Levels 23Account Number 13, 32Addressable Loopcurrent

Pagina 47

UL Listed Commercial and Residential InstallationsThe installation requirements listed below must be met for the fol-lowing grades of service.Grade A

Pagina 48

©1999 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6(416) 665-8460 • Fax (416) 665-7498 • 1-800-387-3630www.dscgrp.

Pagina 49 - Appendix C: ASCII Characters

2Section 2: Installation and Wiring2.1 Planning the SystemNOTE: This system should be installed and serviced byqualified security professionals.The sp

Pagina 50

Section 2: Installation and Wiring3SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2.3 Current Ratings – Alarm Control Panel and Modul

Pagina 51

4the wire to calculate the maximum distance (see“Capacitance Limits” below).4. The total capacitance of the Combus wiring must notexceed 80nF (see “Ca

Pagina 52 - Limited Warranty

Section 2: Installation and Wiring5SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Single End of Line (EOL) All Single EOL zones have a